[Aug 31, 2026] Get Up-To-Date Real Exam Questions for EDI101 with New Materials
Updated EDI101 Certification Exam Sample Questions
NEW QUESTION # 20
An ID Type can be reused for multiple Chronicles master files.
- A. False
- B. True
Answer: A
Explanation:
In Epic's Identity framework, an ID Type is explicitly linked to a single Chronicles master file (e.g., EPT for patients, SER for providers). This one-to-one relationship ensures that the system knows exactly which master file to search when an ID of that type is received in a message. You cannot use a single ID Type definition to identify both a patient and a provider.
NEW QUESTION # 21
For incoming interfaces using Interconnect, which process puts the message on the data queue?
- A. Filer Daemon
- B. Event Daemon
- C. Interconnect
- D. Communications Daemon
Answer: C
Explanation:
When an interface uses Interconnect (Epic ' s HTTPS-based framework) for incoming data, Interconnect receives the message directly via a web service call. Because it is an HTTPS connection rather than a standard TCP/IP socket, Interconnect handles the initial receipt and places the message directly onto the Bridges Data Queue for the Filer Daemon to process.
NEW QUESTION # 22
Which translation table setting allows you to use the values from the category list instead of manually specifying each internal and external value?
- A. Case Sensitive
- B. Many-to-One mapping
- C. Auto-lookup
- D. Default value
Answer: C
Explanation:
When mapping data that exists as an Epic category list (such as Marital Status or Gender), the Auto-lookup feature significantly reduces manual build. When enabled, Bridges automatically pulls in the internal Epic values from the linked category list. The analyst then only needs to provide the corresponding external values from the vendor, rather than manually typing out every possible Epic internal ID and title.
NEW QUESTION # 23
You can look for messages across multiple interfaces in a single search.
- A. False
- B. True
Answer: B
Explanation:
The Message Search activity in Bridges is designed for flexibility. One of its core features is the ability to select multiple interface specifications or even all interfaces within a search. This allows an analyst to track a patient's data across different systems (e.g., searching for both Lab and Pharmacy messages simultaneously) in a single consolidated result list.
NEW QUESTION # 24
Table translations can be either case sensitive or not case sensitive.
- A. False
- B. True
Answer: B
Explanation:
Bridges provides a configuration toggle for Case Sensitivity within translation tables. This is crucial because some external systems might send values like " M " and " m " interchangeably, while others might use case to distinguish between two different codes. Setting this correctly ensures that the interface accurately matches the incoming string to the intended internal value.
NEW QUESTION # 25
Which translation table setting allows you to use the values from the category list instead of manually specifying each internal and external value?
- A. Case Sensitive
- B. Many-to-One mapping
- C. Auto-lookup
- D. Default value
Answer: C
NEW QUESTION # 26
Many interfaces that file patient information are required by default to use Patient Validation and may not start without documenting why the interface should skip validation.
- A. False
- B. True
Answer: B
Explanation:
Because of the high risk associated with misidentifying patients, Epic embeds " hard stops " in the Bridges configuration. For many standard interface types, the system requires Patient Validation to be active. If an organization decides to disable it, the administrator must provide a formal justification within the system before the interface is permitted to start.
NEW QUESTION # 27
Which of the following tools can be used to find messages for a given patient within a specified time range?
(SELECT ALL THAT APPLY)
- A. Message Search
- B. Error Log Report
- C. Message Companion
- D. Interface Messages
Answer: A,C
Explanation:
Both Message Search and the Message Companion are patient-centric tools. Message Search allows for broad criteria including patient identifiers and timestamps across various interfaces. The Message Companion is a specialized tool often accessed directly from patient clinical records, allowing users to see all incoming and outgoing messages specifically for that patient within a defined timeframe.
NEW QUESTION # 28
For which of the following tasks would you use the ID Maintenance activity?
- A. Add an Identity ID to a record
- B. Set an outgoing default mapping
- C. Specify the table to use for mapping
- D. Define new ID Types
Answer: A
Explanation:
The ID Maintenance activity is a record-level tool used by analysts to manage specific identifiers for individual records. If a patient or provider has an incorrect external ID or is missing one necessary for interface communication, an administrator uses this activity to manually add, edit, or delete an Identity ID for that specific record. Defining new ID types (Option B) or configuring global mapping tables (Option D) are high-level configuration tasks performed in different administrative activities, not in the individual ID Maintenance tool.
NEW QUESTION # 29
Which queue is unique to outgoing interfaces?
- A. Data Queue
- B. Holding Queue
- C. Event Queue
- D. Control Queue
Answer: C
Explanation:
The Event Queue is the first stop for outgoing data. When an action occurs in Epic (like a discharge), a trigger is placed in the Event Queue. The Event Daemon then picks up this trigger to build the actual message.
Incoming interfaces do not use an Event Queue because the message is already built by the external system when it arrives.
NEW QUESTION # 30
Which of the following refers to specifically the 2nd component in the 5th field of PID?
- A. PID-5.2
- B. PID-5^2
- C. PID-5[2]
- D. PID52
Answer: A
Explanation:
In HL7 v2 messaging, a standard naming convention is used to identify specific data locations. The format follows Segment-Field.Component.Subcomponent. For example, PID-5 represents the Patient Name field. To specify a component within that field (like the Given Name, which is the 2nd component), a dot is used as a separator. Therefore, PID-5.2 correctly identifies the 2nd component of the 5th field.
NEW QUESTION # 31
The Interface Specification Audit Report will show changes to which of the following items?
- A. Profile Variables
- B. Interface Alerts
- C. Port and IP Address
- D. Message Volume
Answer: A,C
Explanation:
The Specification Audit Report is designed to track configuration changes-the " build " of the interface. It records modifications to critical connectivity settings like the Port and IP Address (Option C) and functional logic changes in Profile Variables (Option D). Operational data like Message Volume (Option A) or active Interface Alerts (Option B) are monitored in real-time activities and are not part of the static specification audit.
NEW QUESTION # 32
What segments are defined as custom in HL7 version 2?
- A. NTE
- B. X-segment
- C. Z-segment
- D. PID
Answer: C
Explanation:
HL7 provides a standard set of segments (like PID for Patient Identity or MSH for Message Header).
However, to allow for site-specific data that doesn ' t fit into standard segments, HL7 reserves the letter " Z " for custom segments. Any segment starting with " Z " (e.g., ZPV, ZCD) is considered a local, non-standard extension defined by the specific healthcare organization or vendor.
NEW QUESTION # 33
How can incoming interfaces determine the ID type to use when looking up a record? (SELECT ALL THAT APPLY)
- A. Match the ID type identifiers from the message to the External System Settings section of the ID Type configuration
- B. Find any record with the received ID and choose an associated ID type
- C. Use a default ID type specified on the interface
- D. Incoming interfaces do not need to lookup an ID type
Answer: A,C
Explanation:
Incoming interfaces must identify the correct ID Type to successfully locate a record in Chronicles. They do this in two primary ways:
* Default ID Type: The interface can be configured with a fallback ID type to use if no other information is provided.
* External System Settings: The interface can look at identifiers within the HL7 message (like the Assigning Authority in PID-3.4) and match them against the " External System Settings " defined in the ID Type configuration . Option C is incorrect because searching without a defined ID type would be inefficient and could lead to incorrect record matches.
NEW QUESTION # 34
The Background Monitor Definition activity allows you to configure an interface to automatically restart after a system downtime, contingent on the status of a different interface.
- A. False
- B. True
Answer: B
Explanation:
The Background Monitor Definition in Bridges is used to manage interface health and automation. It allows administrators to set up dependencies, meaning an interface can be configured to start or restart only if a specific prerequisite interface is already running. This is particularly useful for ensuring that foundational interfaces (like those handling patient identity) are active before clinical data interfaces begin processing.
NEW QUESTION # 35
Which documents can be shared with other software vendors interested in integrating with Epic interfaces?
- A. Interface Reference Guides in Galaxy
- B. Interface Reference Guides in Hyperspace
- C. Technical Specifications on open.epic.com
- D. EDI101 Training Companion
Answer: C
Explanation:
Epic maintains a public-facing portal (open.epic.com) specifically for third-party vendors and developers.
While Interface Reference Guides (IRGs) in Hyperspace or Galaxy contain proprietary information intended for Epic customers, the Technical Specifications on open.epic.com are designed to be shared to facilitate interoperability and standards-based integration.
NEW QUESTION # 36
......